Professional chimney service

Keep the fireplace, drop the smoke and the ash

Describe the Fault

Written Price Before Work
Photos of Every Fault
Repairs Retested On Site
Based in San Fernando
Prices Listed Online
Leak Entry Found First
Level 1 and Level 2 Visits
Written Price Before Work
Photos of Every Fault
Repairs Retested On Site
Based in San Fernando
Prices Listed Online
Leak Entry Found First
Level 1 and Level 2 Visits

What Goes Wrong and What We Do

If splitting wood and hauling ash have lost their appeal, or the open fire always smoked, a gas log set gives a flame at the turn of a valve. We match the burner and logs to the opening, connect or run the gas line, and set up venting to suit the flue and the room. Gas burning is exempt from the district's wood no-burn days. The figure follows the set and the gas work, given after we measure.

Burner and logs matched to the opening
Gas line connected or newly run
Venting chosen for the flue and room
Wall switch or remote control
Flame checked with you before we go

Why owners switch, and what has to be right first

Owners in San Fernando usually switch to gas logs after one too many evenings of smoke in the room, a season of no-burn notices, or plain fatigue with buying and storing wood. A gas log set gives a flame in the existing fireplace without the ash, the creosote or the sweeping that wood needs. It is not an insert. A log set sits in an open firebox and uses the chimney as its vent, so the fireplace still loses heat up the flue, and the look matters more than the warmth. That makes the condition of the fireplace important. A firebox with open joints, a flue with a heavy creosote coat from the wood years, a cracked tile or a cap packed with debris all need attention first, because the gas exhaust has to travel the same path the smoke did. We look at those before recommending a set, and they are repaired or cleaned as part of the plan.

There are two kinds of sets. Vented sets have a tall, lively flame that looks closest to a wood fire, and their exhaust goes up the chimney. That means the damper cannot be fully closed while the set is installed, so a stop is fitted to keep it partly open. Vent-free sets burn more completely, keep the damper shut and put more heat into the room, but they release their exhaust into the room, carry limits on the size of space they can be used in, and include an oxygen-sensing shutoff. Many owners prefer the vented look and the exhaust going outside. We help you weigh the two for your room and the way you use it. On South Coast no-burn days, gas log sets fall outside the wood-burning ban, which is often the reason people in the Valley make the switch in the first place.

Choosing a set and what the price includes

A set that is too small looks lost in the opening, and one that is too large crowds the flame so it hits the logs and leaves soot. Sizing comes from the firebox, so the first visit takes its dimensions and checks whether a gas line already reaches the hearth with a shutoff valve. From there we show you sets that fit, in different log styles and burner sizes, and you pick the look. The written price covers the chosen set, the burner, any gas line and valve work, the damper stop on a vented set, and any repair or cleaning the inspection called for, each listed so you can see what the logs cost and what the fireplace needed anyway. If the flue turns out to need more than a sweep before it can carry gas exhaust, that shows up on the same page with its own figure.

Install day is mostly about placement. The burner pan is seated and connected to the gas line, the ember material is spread, and each log goes on the spot the maker's diagram gives it, since a log a little out of position puts flame against ceramic and starts a soot stain. Once lit, the flame height is set and the fittings are checked with a leak detector. On a vented set we also watch the exhaust go up the flue, because a cold or blocked flue can push it out the front. You are shown the lighting routine and where the shutoff sits. Like any gas burner, a log set wants a yearly cleaning and a check. Owners in San Fernando, Culver City and Pasadena start on the contact page; say whether the fireplace burns wood today and whether there is gas at the hearth.

Four Habits on Every Lanier Chimney Group Job

Retest at the End

The check that showed the fault is run again

Photo of the Cause

You see the failed part before any price

Figure in Writing

Scope and cost on paper ahead of the work

Worst Faults First

Heat and water problems top the list

Other Repairs and Visits

Chimney Sweep

Black crumbs under the damper or a tar smell on hot days: the flue walls are coated and need brushing back to tile.

Signs and fix

Chimney Inspection

Rust drips, gritty mortar or a weak draft? A Level 1 names the part behind it, once a year or whenever something seems off.

Signs and fix

Chimney Repair

Loose brick, open joints, a split top or a ceiling stain by the stack: we find the failed part and rebuild only that.

Signs and fix

Fireplace Inspection

Smoke curling out under the lintel, a cracked firebrick or a grinding damper sends us straight to the room side.

Signs and fix

Fireplace Repair

Crumbling firebrick, a handle that will not budge or a door off its hinge gets taken apart and set right.

Signs and fix

Chimney Level 2 Inspection

For a sale, a past flue fire or a quake: video of the lining shows the joints a flashlight never reaches.

Signs and fix

Chimney Cap Installation

Rain hissing in the firebox, feathers in the ash or rust on the crown mean the top is open or the cap has failed.

Signs and fix

Chimney Flashing Repair

A ceiling stain that grows after each storm usually starts at the metal seam where roofing meets brick.

Signs and fix

Chimney Masonry Repair

Sand on the roof, joints you can scrape out with a key and brick faces popping off mean the stack is weakening.

Signs and fix

Chimney Rebuilds

A stack that leans, pulls from the wall or has loose top courses gets taken down and laid up again.

Signs and fix

Fireplace Cleaning

A sour ash smell on humid days or a grate buried under old fires calls for a firebox cleaning.

Signs and fix

Gas Fireplace Cleaning

Orange flame tips, white haze on the glass or a flickering pilot usually trace back to dust in the burner.

Signs and fix

Gas Fireplace Repair

No flame at the switch, a pilot that dies or a dead remote: we test until the failed part shows itself.

Signs and fix

Fireplace Remodel

Lifting tile, a mantel pulling off the wall or an opening that always smoked is a cue to rebuild the whole face.

Signs and fix

Fireplace Inserts

A cold room beside a roaring fire, or a draft from the opening all winter, points to a sealed insert.

Signs and fix

Pellet Stove Repair

A pellet stove that beeps, piles pellets in the pot or blackens its glass has a fault we can track down.

Signs and fix

Wood Stove Repair

Glass that blackens in an hour, smoke at the door or a fire you cannot turn down means seals or baffles are worn.

Signs and fix

Chimney Seismic Retrofit

A crack ringing the stack near the roof, or a gap at the siding, means the brick needs bracing before the next quake.

Signs and fix

Chimney Crown Repair

Grey chips in the gutter, rust under the cap or water in the flue often trace back to a split top slab.

Signs and fix

Dryer Vent Cleaning

Towels that need two cycles, a burning lint smell or a flap that barely lifts outside mean the duct is packed.

Signs and fix

Chimney Liner Installation

Cracked clay tile on a camera report, or a new stove going in, both lead to a new stainless lining.

Signs and fix

Chimney Leak Repair

Water on the hearth, a stain beside the breast or a damp smell after rain: we find the entry point before fixing it.

Signs and fix

Chimney Waterproofing

Brick that stays dark for days after rain, or a white salt crust, shows a stack soaking up water.

Signs and fix

Chimney Damper Repair

Cold air pouring from a fireplace you never light, or a plate that will not swing up, means the damper has failed.

Signs and fix

Chimney Chase Cover

Rust streaks down the siding, water in a metal firebox or a sagging lid point to a failing chase top.

Signs and fix
Call (747) 224-9315