Professional chimney service

A pellet stove that quits usually tells you why

Describe the Fault

Written Price Before Work
Photos of Every Fault
Repairs Retested On Site
Based in San Fernando
Prices Listed Online
Leak Entry Found First
Level 1 and Level 2 Visits
Written Price Before Work
Photos of Every Fault
Repairs Retested On Site
Based in San Fernando
Prices Listed Online
Leak Entry Found First
Level 1 and Level 2 Visits

What Goes Wrong and What We Do

Beeping and a dead fire, pellets heaping in the pot, black smoke on the glass. A pellet stove leans on many small parts: a motor turning a screw, a hot rod lighting the fuel, fans moving air, a board reading sensors. One weak link stalls the lot. We strip out the ash, test each part in place, replace the one that failed and relight. Parts are priced before ordering.

Ash cleared from pot, traps and exhaust path
Feed motor and screw tested
Hot rod igniter metered
Fans and sensors checked
Error history read before relighting

What the symptom says about the stove

Pellet stoves fail out loud. An error light blinks, the fire dies twenty minutes into a burn, the hopper stays full while the burn cup sits empty, or the room picks up a faint smoky smell. Each complaint narrows the search. Shutdowns soon after lighting usually trace to the safety switches, which stop the stove when they sense weak exhaust flow or the wrong temperature, and the cause behind that is most often ash: a packed vent, a choked burn cup, a clogged passage behind the firebox panels. A cold stove with pellets sitting in the cup points to the igniter. A cup that never receives pellets points to the feed screw or its motor, or to an overlong pellet or a lump of sawdust jammed in the chute. A smoky smell means exhaust is escaping from the vent joints or the door seal, and that one ends the stove's use until it is fixed.

Running a stove that has started to act up tends to make it worse. Owners clear an error and restart it over and over, and each failed start leaves unburned pellets in the cup that cake and make the next start harder. A vent that is partly blocked forces the exhaust fan to work harder and can push smoke out of loose joints into the room, and pellet exhaust carries carbon monoxide like the exhaust of any other fire. Igniters and fan motors that are struggling run hot and fail sooner. In San Fernando most pellet stoves only run a few months a year, so the common pattern is a stove that worked last March and will not start in November, often because ash left in it over the summer drew in moisture and hardened. A cleaning and a check before the season usually catches that before the first cold night.

The repair visit and pricing

We start with a full cleaning, because many pellet faults disappear once the ash is out of the burn cup, the heat exchanger passages and the vent. That also lets us see the parts clearly. Then we test the parts that match the symptom: the igniter for resistance, the switches for continuity, the feed motor under load, the fans for speed and noise. Door and hopper seals are checked for a tight fit. The vent run is looked over from the stove to the outside, including the joints, which must be sealed on a pellet vent, and the termination outside the house. When the failed part is found, you get its price and the labor in writing. Some stove makers keep parts in stock for years; others have closed, and for those we may be able to fit a compatible part, which we tell you about before ordering.

Pellet stove repair is priced per job rather than from a list, because a cleaning and a new seal is a different visit from a new control board. Each written figure shows the part and the time separately. If the stove is old and the cost of its repairs is approaching the price of a new unit, we say so and lay out both paths, but the decision stays yours. Many owners in San Fernando, Canoga Park and Pasadena book a cleaning before the season so the first cold night does not turn into a service call. When you book through the contact page, a few words on how the stove behaves in the minutes before it quits give us a head start, and so does any code the display shows. We bring the common wear parts for the brands we see most in the Valley.

Four Habits on Every Lanier Chimney Group Job

Retest at the End

The check that showed the fault is run again

Photo of the Cause

You see the failed part before any price

Figure in Writing

Scope and cost on paper ahead of the work

Worst Faults First

Heat and water problems top the list

Other Repairs and Visits

Chimney Sweep

Black crumbs under the damper or a tar smell on hot days: the flue walls are coated and need brushing back to tile.

Signs and fix

Chimney Inspection

Rust drips, gritty mortar or a weak draft? A Level 1 names the part behind it, once a year or whenever something seems off.

Signs and fix

Chimney Repair

Loose brick, open joints, a split top or a ceiling stain by the stack: we find the failed part and rebuild only that.

Signs and fix

Fireplace Inspection

Smoke curling out under the lintel, a cracked firebrick or a grinding damper sends us straight to the room side.

Signs and fix

Fireplace Repair

Crumbling firebrick, a handle that will not budge or a door off its hinge gets taken apart and set right.

Signs and fix

Chimney Level 2 Inspection

For a sale, a past flue fire or a quake: video of the lining shows the joints a flashlight never reaches.

Signs and fix

Chimney Cap Installation

Rain hissing in the firebox, feathers in the ash or rust on the crown mean the top is open or the cap has failed.

Signs and fix

Chimney Flashing Repair

A ceiling stain that grows after each storm usually starts at the metal seam where roofing meets brick.

Signs and fix

Chimney Masonry Repair

Sand on the roof, joints you can scrape out with a key and brick faces popping off mean the stack is weakening.

Signs and fix

Chimney Rebuilds

A stack that leans, pulls from the wall or has loose top courses gets taken down and laid up again.

Signs and fix

Fireplace Cleaning

A sour ash smell on humid days or a grate buried under old fires calls for a firebox cleaning.

Signs and fix

Gas Fireplace Cleaning

Orange flame tips, white haze on the glass or a flickering pilot usually trace back to dust in the burner.

Signs and fix

Gas Fireplace Repair

No flame at the switch, a pilot that dies or a dead remote: we test until the failed part shows itself.

Signs and fix

Fireplace Remodel

Lifting tile, a mantel pulling off the wall or an opening that always smoked is a cue to rebuild the whole face.

Signs and fix

Fireplace Inserts

A cold room beside a roaring fire, or a draft from the opening all winter, points to a sealed insert.

Signs and fix

Wood Stove Repair

Glass that blackens in an hour, smoke at the door or a fire you cannot turn down means seals or baffles are worn.

Signs and fix

Gas Logs

An open hearth you no longer want to tend, or one that always smoked, can take ceramic logs on a gas burner.

Signs and fix

Chimney Seismic Retrofit

A crack ringing the stack near the roof, or a gap at the siding, means the brick needs bracing before the next quake.

Signs and fix

Chimney Crown Repair

Grey chips in the gutter, rust under the cap or water in the flue often trace back to a split top slab.

Signs and fix

Dryer Vent Cleaning

Towels that need two cycles, a burning lint smell or a flap that barely lifts outside mean the duct is packed.

Signs and fix

Chimney Liner Installation

Cracked clay tile on a camera report, or a new stove going in, both lead to a new stainless lining.

Signs and fix

Chimney Leak Repair

Water on the hearth, a stain beside the breast or a damp smell after rain: we find the entry point before fixing it.

Signs and fix

Chimney Waterproofing

Brick that stays dark for days after rain, or a white salt crust, shows a stack soaking up water.

Signs and fix

Chimney Damper Repair

Cold air pouring from a fireplace you never light, or a plate that will not swing up, means the damper has failed.

Signs and fix

Chimney Chase Cover

Rust streaks down the siding, water in a metal firebox or a sagging lid point to a failing chase top.

Signs and fix
Call (747) 224-9315